Skip to content
Primary Menu

Education, Presentation, Publication

Funding & Recognition

Effects of Dual Fluoroscopy and Skin Marker Motion Capture Scaling on Muscle Moment Arms in OpenSim

Semester: Summer 2026


Presentation description

Two common methods of motion capture data collection used for musculoskeletal modeling are skin marker motion capture (SM) and dual fluoroscopy motion capture (DF). SM is simpler to conduct, but can be prone to error due to soft tissue artifact. DF can track bone movement more accurately, but requires significant data processing time. Musculoskeletal modeling can be used to study the mechanics of cam femoroacetabular impingement syndrome (FAIS), a condition characterized by pain in the hip caused by subtle bony growth on the femur. DF is extremely useful for research of this patient population because of the subtle kinematic differences these patients display, but SM is the more accessible method to clinical assessment of patients. This case study assesses how the two motion capture methods affect muscle moment arms estimation in OpenSim. A single patient was imaged in a static standing position with both SM and DF motion capture methods. Data from each method was then used to scale a generic lower-body model in OpenSim. Moment arms were calculated across the entire range of motion of the rectus femoris, iliacus, psoas, obturator externus, and gluteus maximus in python. The obturator externus, a hip rotator muscle, differed greatly across all hip flexion/extension joint angles, specifically 137% between SM and DF scaling at 90.3° of hip flexion (approximating average squat flexion angle), while the remaining muscles showed little to no difference between the two models across all of extension and most of flexion. The obturator externus is the only included muscle responsible for hip rotation, which may explain the difference in calculated moment arms from model scaling due to the complexity of rotation compared to extension/flexion that DF can capture more accurately than SM. Identifying how muscle moment arms are affected by different motion capture methods can help researchers choose the method that balances efficiency, accuracy, and accessibility for a particular muscle group or patient population of interest.
Presenter Name: Katie Wise
Presentation Type: Poster
Presentation Format: In Person
Presentation #17
College: Medicine
School / Department: Orthopaedics
Research Mentor: Andrew Anderson
Additional Mentor: Brooklyn Vargas
Time: 10:40 AM
Physical Location or Zoom link:

Henriksen